Confined
Space Information - Addendum B
1) CONFINED SPACE INFORMATION: If work is being done in a confined space that can change conditions (welding, cutting.....), then a permit is required. 2) VENTILATION GUIDELINE: Unless specified, five (5) minutes with mechanical ventilation equipment prior to entry. 3) ATTENDANT REQUIREMENT: When an attendant is required at a minimum the rescue trailer must be on site. Additional requirements will be listed if needed. AGATE HALL:Location: North CATE AuditoriumNature of Hazards: Oxygen Deficiency, Information Sheet, Safety Precautions: Information Sheet Posted, Atmospheric Test Equipment Required: Compatible Communication Equipment-Radio Comments: Hard hat if entering beyond sump pump AUTZEN STADIUM:Location: Water Control Valve North of Stadium ClubNature of Hazards: Oxygen Deficiency, Flammable Gases/Vapors Safety Precautions: Permit Posted, Atmospheric Test, Traffic Control, Ventilation/Purge Equipment Required: Compatible Communication Equipment-Radio, Hard Hat, Barricades/Cones, Ventilation Equipment Comments: Attendant Required AUTZEN STADIUM: Location: Restroom Vent Ducting Near Top of East Berm of Stadium Nature of Hazards: Oxygen Deficiency Safety Precautions: Information Sheet Posted, Atmospheric Test Equipment Required: Compatible Communication Equipment - Radio, Hard Hat AUTZEN STADIUM:Location: Restroom Vent Ducting Near Top of West Berm of StadiumNature of Hazards: Oxygen Deficiency Safety Precautions: Infomation Sheet Posted, Atmospheric Test Equipment Required: Compatible Communication Equipment-Radio, Hard Hat BEAN CISTERN:Location: Off tunnels outside Bean mechanical roomNature of Hazards: Oxygen Deficiency, Flooding Safety Precautions: Permit Posted, Atmospheric Test, 2 Person tunnel rule Equipment Required: Hard Hat, Flashlight, Compatible Communication Equipment-Radio CASNOVA CENTER:Location: Water Control Valve North of Casanova CenterNature of Hazards: Oxygen Deficiency Safety Precautions: Permit Posted, Atmospheric Test, Ventilation/Purge, Traffic Control Equipment Required: Compatible Communication Equipment-Radio, Hard Hat, Barricades/Cones, Ventilation Equipment Comments: Attendant Required CASANOVA CENTER:Location: Heat Furnace Boilers (2) in Mechanical RoomNature of Hazards: Oxygen Deficiency Posted, Flammable Gases/Vapors Safety Precautions: Permit Posted, Atmospheric Test Equipment Required: Compatible Communication Equipment-Radio, Monitor, Ventilation Equipment Comments: Attendant Required; Lockout/Tagout (Blank Bleed) Gas Source CASANOVA CENTER:Location: Water Heating Tanks (3) in Mechanical RoomNature of Hazards: Oxygen Deficiency, Water Engulfment Safety Precautions: Permit Posted, Atmospheric Test Equipment Required: Compatible Communication Equipment-Radio, Monitor, Ventilation Equipment Comments: Attendant Required; Lockout/Tagout Water Source CASCADE HALL/CASCADE ANNEX:Location: Oil Separator in Sidewalk Between BuildingsNature of Hazards: Oxygen Deficiency, Flammable Gases/Vapors, Toxic Gases/Vapors, Material Harmful to the Skin Safety Precautions: Permit Posted, Atmospheric Test, Pedestrian Control, Other-Both Doors Open Equipment Required: Compatible Communication Equipment-Radio, Hard Hat, Barricades/Cones, Both Doors Open CENTRAL POWER STATION:Location: #1 Boiler Exhaust BreechingNature of Hazards: Oxygen Deficiency, Toxic Gases/Vapors Safety Precautions: Permit Posted, Atmospheric Test, Ventilation/Purge Equipment Required: Compatible Communication Equipment-Radio, Monitor Comments: Attendant Required; Lockout/Tagout-Gas Lines, Oil Lines and Steam Atomization Lines CENTRAL POWER STATION:Location: #1 Boiler Fire BoxNature of Hazards: Oxygen Deficiency, Toxic Gases/Vapors Safety Precaution: Permit Posted, Atmospheric Test, Ventilation/Purge Equipment Required: Compatible Communication Equipment-Radio, Monitor Comments: Attendant Required; Lockout/Tagout-Gas Lines, Oil Lines and Steam Atomization Lines CENTRAL POWER STATION:Location: #1 Boiler Mud DrumNature of Hazards: Oxygen Deficiency, Steam/Water Engulfment, Toxic Gases/Vapors Safety Precautions: Permit Posted, Atmospheric Test, Ventilation/Purge Equipment Required: Compatible Communication Equipment-Radio, Monitor, Ventilation Equipment Comments: Attendant Required; Lockout/Tagout on Main Steam, Feedwater and Steam Blanket Systems CENTRAL POWER STATION:Location: #1 Boiler Steam DrumNature of Hazards: Oxygen Deficiency, Steam/Water Engulfment, Toxic Gases/Vapors Safety Precautions: Permit Posted, Atmospheric Test, Ventilation/Purge Equipment Required: Compatible Communication Equipment-Radio, Monitor, Ventilation Equipment Comments: Attendant Required; Lockout/Tagout on Main Steam, Feedwater, Steam Blanket System CENTRAL POWER STATION:Location: #4 Boiler Air Heater West EndNature of Hazards: Oxygen Deficiency, Toxic Gases/Vapors Safety Precautions: Permit Posted, Atmospheric Test, Ventilation/Purge Equipment Required: Compatible Communication Equipment-Radio, Monitor,Ventilation Equipment Comments: Attendant Required; Lockout/Tagout-Gas Lines, Oil Lines and Steam Atomization Lines CENTRAL POWER STATION:Location: #4 Boiler Exhaust BreechingNature of Hazards: Oxygen Deficiency, Toxic Gases/Vapors Safety Precautions: Permit Posted, Atmospheric Test, Ventilation/Purge Equipment Required: Compatible Communication Equipment-Radio, Monitor, Ventilation Equipment Comments: Attendant Required; Lockout/Tagout-Gas Lines, Oil Lines and Steam Atomization Lines CENTRAL POWER STATION:Location: #4 Boiler Fire BoxNature of Hazards: Oxygen Deficiency, Toxic Gases/Vapors Safety Precautions: Permit Posted, Atmospheric Test, Ventilation/Purge Equipment Required: Compatible Communication Equipment-Radio, Monitor, Ventilation Equipment Comments: Attendant Required; Lockout/Tagout-Gas Lines, Oil Lines and Steam Atomization Lines CENTRAL POWER STATION:Location: #4 Boiler Mud DrumNature of Hazards: Oxygen Deficiency, Steam/Water Engulfment, Toxic Gases/Vapors Safety Precautions: Permit Posted, Atmospheric Test, Ventilation/Purge Equipment Required: Compatible Communication Equipment-Radio, Monitor, Ventilation Equipment Comments: Attendant Required; Lockout/Tagout on Main Steam, Feed Water and Steam Blanket Systems CENTRAL POWER STATION:Location: #4 Boiler Steam DrumNature of Hazards: Oxygen Deficiency, Steam/Water Engulfment, Toxic Gases/Vapors Safety Precautions: Permit Posted, Atmospheric Test, Ventilation/Purge Equipment Required: Compatible Communication Equipment-Radio, Monitor, Ventilation Equipment Comments: Attendant Required; Lockout/Tagout on Main Steam, Feed Water and Steam Blanket Systems CENTRAL POWER STATION:Location: Horizontal D.A. Tank (Third Level)Nature of Hazards: Oxygen Deficiency, Steam/Water Engulfment, Toxic Gases/Vapors Safety Precautions: Permit Posted, Atmospheric Test, Ventilation/Purge Equipment Required: Compatible Communication Equipment-Radio, Monitor, Ventilation Equipment Comments: Attendant Required; Lockout/Tagout on Steam Condensate/Make-Up, Feed Water Systems, Chemical Feed Lines CENTRAL POWER STATION:Location: Old Vertical D.A. Tank (Third Level)Nature of Hazards: Oxygen Deficiency, Steam/Water Engulfment, Toxic Gases/Vapors Safety Precautions: Permit Posted, Atmospheric Test, Ventilation/Purge Equipment Required: Compatible Communication Equipment-Radio, Monitor, Ventilation Equipment Comments: Attendant Required; Lockout/Tagout on Steam Condensate/Make-Up, Feed Water and Chemical Feed Systems CENTRAL POWER STATION:Location: RO Make Up Tank - Ground LevelNature of Hazards: Oxygen Deficiency, Engulfment, Toxic Gases/Vapors Safety Precautions: Permit Posted, Atmospheric Test, Ventilation/Purge If Needed, Equipment Required: Communication Equipment, Hard Hat, Harness, Lifeline, Ventilation Equipment, Retrieval Equipment Comments: Attendant Required, Harness w/ Lifeline, Hard Hat, Lockout / Tagout Water Supply CENTRAL POWER STATION:Location: Surge Tank (Fifth Level)Nature of Hazards: Oxygen Deficiency, Steam/Water Engulfment Safety Precautions: Permit Posted, Atmospheric Test Equipment Required: Compatible Communication Equipment-Radio, Monitor Comments: Attendant Required; Lockout/Tagout on Campus Condensate, EWEB Condensate, Water Softener Discharge CENTRAL POWER STATION:Location: Steam IntertieNature of Hazards: Oxygen Deficiency, Heat Safety Precautions: Permit Posted, Atmospheric Test Equipment Required: Compatible Communication Equipment-Radio, Hard Hat ELECTRICAL VAULT:Location: AllNature of Hazards: Oxygen Deficiency, Electrical Shock Safety Precautions: Permit Posted, Atmospheric Test, Traffic Control, Pedestrian Control, Lockout/Tagout Where Applicable, Maintain 25" minimum approach distance, 2 Qualified high voltage electricians required if unable to maintain 25" clearance Equipment Required: Hard Hat, Compatible Communication Equipment-Radio, Special Conditions/Requirements: OR-OSHA 1910.269 requires a CPR trained attendant (not a certified Confined Space Attendant / Rescuer.) PLEASE NOTE ON PERMIT that this attendant is fulfilling a High Voltage(HV), not a Confined Space, requirement. ESSLINGER/LEIGHTON:Location: Filter/Trap PitNature of Hazards: Oxygen Deficiency, Toxic Gases/Vapors, Material Harmful to the Skin Safety Precautions: Permit Posted, Atmospheric Test Equipment Required: Compatible Communication Equipment-Radio, Hard Hat ESSLINGER/LEIGHTON:Location: Pipe Chute North of PoolNature of Hazards: Oxygen Deficiency Safety Precautions: Information Sheet Posted, Atmospheric Test Equipment Required: Compatible Communication Equipment-Radio GERLINGER HALL:Location: Chemical Mixing Pit in Exterior Building West EndNature of Hazards: Oxygen Deficiency, Toxic Gases/Vapors Safety Precautions: Permit Posted, Atmospheric Test Equipment Required: Compatible Communication Equipment-Radio, Harness,Lifeline Comments: Attendant Required HUESTIS HALL:Location: Backflow Preventer Valve Vault in 13th Ave. SidewalkNature of Hazards: Oxygen Deficiency Safety Precautions: Information Sheet Posted, Atmospheric Test Equipment Required: Compatible Communication Equipment-Radio KLAMATH HALL:Location: Chemical Exhaust, Building Roof KNIGHT LAW SCHOOL:Location: Three Vaults in West Side Front Lawn
(Backflow, Irrigation Controls, and EWEB connection) LILLIS BUSINESS COMPLEX:Location: Backflow Device in Vault at SW Corner of Peterson HallNature of Hazards: Oxygen Deficiency Safety Precautions: Information Sheet Posted, Atmospheric Test Equipment Required: Compatible Communication Equipment LIVING LEARNING CENTER:Location: Water Control Valve Vault Along 15th AvenueNature of Hazards: Oxygen Deficiency Safety Precautions: Information Sheet, Atmospheric Test, Traffic/Ped Control Equipment Required: Compatible Communication Equipment, Barricade/Cones Comments: MANHOLES:Location: All, Except Tunnel AccessesNature of Hazards: Oxygen Deficiency Safety Precautions: Information Sheet, Atmospheric Test, Traffic Control, Pedestrian Control Equipment Required: Hard Hat, Barricades/Cones For All; Retrieval Equipment, Harness, Lifeline if > 6' Depth for fall protection Comments: MANY NATIONS LONGHOUSE:Location: Vaults (Electrical and Utilities) on West SideNature of Hazards: Oxygen Deficiency, Electrical Shock Safety Precautions: Permit Posted, Atmospheric Test, Traffic Control, Pedestrian Control, Lockout/Tagout Where Applicable, Maintain 25" minimum approach distance, 2 Qualified high voltage electricians required if unable to maintain 25" clearance Equipment Required: Hard Hat, Compatible Communication Equipment-Radio, Special Conditions/Requirements: OR-OSHA 1910.269 requires and CPR trained attendant (not a certified Confined Space Attendant / Rescuer.) PLEASE NOTE ON PERMIT that this attendant is fulfilling a High Voltage(HV) requirement not a Confined Space requirement MILLRACE STUDIO II:Location: Steam Connection Vault in road to North MILLRACE STUDIO III:Location: Water Valve Box West End MOSS STREET CHILD CARE:Location: Water Control Valve Vault Along 17th AvenueNature of Hazards: Oxygen Deficiency Safety Precautions: Information Sheet Posted, Atmospheric Test, Traffic/Ped Control Equipment Required: Compatible Communication Equipment, Barricade/Cones Comments:
MUSEUM OF ART:Location: Backflow Device in VaultNature of Hazards: Oxygen Deficiency, Flooding Safety Precautions: Information Sheet Posted, Atmospheric Test Equipment Required: Compatible Communication Equipment NORTHSITE B:
|

| Updated by SLM on February 5, 2008 Please send Comments to the webmaster. |